checkCIF/PLATON report (publication check)

No syntax errors found.                               CIF dictionary
Please wait while processing .... Interpreting this report
Datablock: shelxl
Bond precision: C-C = 0.0233 A Wavelength=0.71073
Cell: a=9.7066(8) b=15.2493(10) c=15.1463(15)
alpha=90 beta=128.854(4) gamma=90
Temperature: 546 K
Calculated Reported
Volume 1745.9(3) 1745.9(3)
Space group P 21/c P 21/c
Hall group -P 2ybc -P 2ybc
Moiety formula C15 H27 Cl N P Pt C15 H27 Cl N P Pt
Sum formula C15 H27 Cl N P Pt C15 H27 Cl N P Pt
Mr 482.88 482.89
Dx,g cm-3 1.837 1.837
Z 4 4
Mu (mm-1) 8.270 8.270
F000 936.0 936.0
F000' 930.80
h,k,lmax 12,19,18 12,19,18
Nref 3602 3461
Tmin,Tmax 0.521,0.609 0.523,0.610
Tmin' 0.511
Correction method= AbsCorr=MULTI-SCAN
Data completeness= Ratio = 0.961 Theta(max)= 26.460
R(reflections)= 0.0657( 2013) wR2(reflections)= 0.1440( 3461)
S = 0.958 Npar= 179

The following ALERTS were generated. Each ALERT has the format
       test-name_ALERT_alert-type_alert-level.
Click on the hyperlinks for more details of the test.

Alert level B PLAT342_ALERT_3_B Low Bond Precision on C-C Bonds (x 1000) Ang ... 23
Alert level C PLAT029_ALERT_3_C _diffrn_measured_fraction_theta_full Low ....... 0.97 PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for C6
0 ALERT level A = In general: serious problem 1 ALERT level B = Potentially serious problem 2 ALERT level C = Check and explain 0 ALERT level G = General alerts; check 0 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 1 ALERT type 2 Indicator that the structure model may be wrong or deficient 2 ALERT type 3 Indicator that the structure quality may be low 0 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check


Publication of your CIF

You should always attempt to resolve as many as possible of the alerts in all categories. Often the minor alerts point to easily fixed oversights, errors and omissions in your CIF or refinement strategy, so attention to these fine details can be worthwhile. In order to resolve some of the more serious problems it may be necessary to carry out additional measurements or structure refinements. However, the nature of your study may justify the reported deviations from the submission requirements of the journal and these should be commented upon in the discussion or experimental section of a paper - after all, they might represent an interesting feature.

If you wish to submit your CIF for publication in Acta Crystallographica Section C or E, you should upload your CIF via the web. If your CIF is to form part of a submission to another IUCr journal, you will be asked, either during electronic submission or by the Co-editor handling your paper, to upload your CIF via our web site.


PLATON version of 27/11/2007; check.def file version of 27/11/2007
Datablock shelxl - ellipsoid plot

Download CIF editor (enCIFer) from the CCDC
Test a new CIF entry